IEC60092-353其主要测试项目总结如下:
常规电缆:
1、导体电阻 Conductor resistance (IEC 60228,IEC 60092-350:2016 Section 350)
2、耐压试验 Voltage test
3、护套耐压试验 Voltage test on sheath
4、绝缘电阻 Insulation resistance test
5、导体检查 Conductor examination
6、绝缘厚度 Thickness of insulation
7、非金属护套厚度 Thickness of nonmetallic sheaths
8、外径 External diameter
9、热延伸 Hot set test
10、编织覆盖密度 Coverage density of braid
11、最高额定温度下的绝缘电阻 Insulation resistance measurement at maximum rated temperature (IEC 60092-360)
12、浸水后AC电容增长 Increase in AC capacitance after immersion in water
13、热老化前后绝缘机械性能 Mechanical properties of insulation before and after ageing (IEC 60092-350 Section 8.4 IEC 60092-360)
14、热老化前后护套机械性能 Mechanical properties of sheath before and after ageing
15、兼容性测试 Compatibility test( IEC 60092-360)
16、热失重 Loss of mass test
17、高温性能 Behavior at high temperature
18、低温性能 Behavior at low temperature
19、铜线涂层测试 Test for coating of copper wires
20、镀锌测试 Galvanizing test (IEC 60092-350 Section 8.12 ISO 7989-2 Section 5.3)
21、耐热冲击开裂 Resistance to cracking heat shock
22、耐臭氧 Ozone resistance ( IEC 60092-350 Section 8.14 IEC 60092-360)
23、浸热油 Hot oil immersion
24、燃烧测试 Fire-retardant test
25、硬度测量 Determination of hardness
26、弹性模量测量 Determination of modulus of elasticity
27、标志耐久性 Durability of marking
28、酸性气体释放 Acid gas emission (IEC 60754-1)
29、pH和导电性 pH and conductivity (IEC 60754-2)
30、氟含量测试 Fluorine content test (IEC 60684-2)
31、烟释放测试 Smoke emission test (IEC 60092-350 Section 8.17.3)
32、耐火测试 Test for fire resistance (IEC 60092-350 Section 8.17.7)
33、低温性能特定测试 Additional tests required for specific performances
34、增强浸热油 Enhanced hot oil immersion
35、钻液测试 Drilling fluid tes