EN45545-2: Fire protection of railway vehicles – Part 2: Requirement for fire behaviours of materials and components
EN 45545-2: 轨道车辆的防火-电线电缆防火测试(R15 / R16)
EN 45545-2欧标线缆防火测试-概述
针对电线电缆,根据EN45545-2标准,按照项目 R15/R16执行测试。测试项目主要包含了单根燃烧,成束燃烧,烟密度和烟毒性测试,借鉴了DIN 5510-2线缆的测试方法。
EN 45545-2欧标线缆防火测试-性能要求
EN 45545-2 R15 车内线缆
测试项目 | 等级要求 | ||
HL1 | HL2 | HL3 | |
EN 60332-1-2 | burned part ≤ 540 unburned part > 50 | burned part ≤ 540 unburned part > 50 | burned part ≤ 540 unburned part > 50 |
EN 60332-3-24(D≥12mm) | <2.5m | <2.5m | <2.5m |
EN 50305Clause 9.1.1(6 < D < 12 mm) | <2.5m | <2.5m | <2.5m |
EN 50305Clause 9.1.2(D ≤ 6 mm) | <1.5m | <1.5m | <1.5m |
EN 61034-2 | – | >25% | >50% |
EN 50305Clause 9.2 ITC | <10 | <10 | <6 |
EN 45545-2 R16 车外线缆
测试项目 | 等级要求 | ||
HL1 | HL2 | HL3 | |
EN 60332-1-2 | burned part ≤ 540 unburned part > 50 | burned part ≤ 540 unburned part > 50 | burned part ≤ 540 unburned part > 50 |
EN 60332-3-24(D≥12mm) | <2.5m | <2.5m | <2.5m |
EN 50305Clause 9.1.1(6 < D < 12 mm) | <2.5m | <2.5m | <2.5m |
EN 50305Clause 9.1.2(D ≤ 6 mm) | <1.5m | <1.5m | <1.5m |
EN 61034-2 | >25% | >50% | >70% |
EN 50305Clause 9.2 ITC | <10 | <10 | <6 |
EN 45545-2欧标线缆防火测试-参考标准
EN 45545-2: 轨道车辆的防火保护-第2部分:材料和元件的防火要求
DIN 5510-2 机车电线电缆阻燃测试
NFF16-102铁路车辆防火材料的选择-电力设备的应用
EN 60332-1-2:2005-06单根绝缘电线或电缆在火焰条件下的垂直燃烧测试
EN 60332-3-24 垂直安装的成束电线电缆火焰垂直蔓延试验——C 类
EN 61034测量电线在特定条件下产生的烟密度
EN 50305 铁路设施-具有特殊防火性能的轨道车辆电缆-试验方法
EN 45545-2欧标线缆防火测试-试验方法
EN 60332-1-2:2005-06单根绝缘电线或电缆在火焰条件下的垂直燃烧测试
EN 60332-3-24 垂直安装的成束电线电缆火焰垂直蔓延试验(D≥12mm)
EN 50305:2002, Clause 9.1.1 成束燃烧测试(6 mm < D < 12 mm)
EN 50305:2002, Clause 9.1.2成束燃烧测试(D ≤ 6 mm)
EN 61034-2测量电线在特定条件下产生的烟密度
EN 50305 Clause 9.2 烟雾毒性测试ITC
电线电缆测试标准参考
IEC 60754-1, EN 50267-2-1 ( 无卤测试)
IEC 60754-2, EN 50267-2-2 ( 气体腐蚀性测试)
NES 02-713, NFC 20-454 ( 毒性指数测试)
IEC 61034, EN 50268-2 ( 烟密度测试)
IEC 60332-1, EN 50265-2-1 ( 单根电缆/ 电线火焰传播测试)
IEC 60332-3, EN 50266-2, NF C 32-070 ( 成束电缆/ 电线火焰传播测试)